Englisch-Deutsch Übersetzung für "BOD"
13 Typ {m} [ugs.] [Mensch]. Übersetzung im Kontext von „Bod.“ in Englisch-Deutsch von Reverso Context: bod. Englisch-Deutsch-Übersetzungen für bod im Online-Wörterbuch courageandcraftla.com (Deutschwörterbuch).Bod Deutsch Main Difference – BOD vs COD Video
Rocket and Professor Hulk Meets Fat Thor Scene - AVENGERS 4 ENDGAME (2019) Movie CLIP 4K


The rate of the oxygen consumption depends on the temperature, pH, present in microorganisms, and the type of organic material in water.
The greater the BOD in a particular water body, the lesser oxygen is available for the aquatic life forms in that particular water body. Aquatic life forms would be stressed, suffocate and ultimately die due to high BOD.
The BOD test bottles at a laboratory of a wastewater treatment plant are shown in figure 1. Figure 1: BOD test bottles.
COD refers to the chemical oxygen demand, which measures the amount of DO, required by the decomposition of organic matter and the oxidation of inorganic chemicals like ammonia and nitrite.
COD measurements are commonly made with the samples of wastewater or natural water, which are contaminated by domestic and industrial wastes.
A closed water sample is incubated with a strong oxidant like potassium dichromate K 2 Cr 2 O 7 in combination with boiling sulfuric acid H 2 SO 4 under a specific temperature for a specified period of time.
The amount of cellulose in water is only measured by COD. The plants which treat wastewater from the commercial operations measure COD. Ariel view of a wastewater treatment plant is shown in figure 2.
Figure 2: Wastewater Treatment Plant. The amount of oxygen required to completely oxidize the organic compounds to carbon dioxide and water through generations of microbial growth, death, decay, and cannibalism is total biochemical oxygen demand total BOD.
Total BOD is of more significance to food webs than to water quality. Dissolved oxygen depletion is most likely to become evident during the initial aquatic microbial population explosion in response to a large amount of organic material.
If the microbial population deoxygenates the water, however, that lack of oxygen imposes a limit on population growth of aerobic aquatic microbial organisms resulting in a longer term food surplus and oxygen deficit.
A standard temperature at which BOD testing should be carried out was first proposed by the Royal Commission on Sewage Disposal in its eighth report in This general standard should be prescribed either by Statute or by order of the Central Authority, and should be subject to modifications by that Authority after an interval of not less than ten years.
This temperature may be significantly different from the temperature of the natural environment of the water being tested.
Although the Royal Commission on Sewage Disposal proposed 5 days as an adequate test period for rivers of the United Kingdom of Great Britain and Ireland , longer periods were investigated for North American rivers.
Incubation periods of 1, 2, 5, 10 and 20 days were being used into the midth century. This 5-day BOD test result may be described as the amount of oxygen required for aquatic microorganisms to stabilize decomposable organic matter under aerobic conditions.
Although these fauna will continue to exert biochemical oxygen demand as they die, that tends to occur within a more stable evolved ecosystem including higher trophic levels.
The Royal Commission on River Pollution , established in , and the formation of the Royal Commission on Sewage Disposal in led to the selection in of BOD 5 as the definitive test for organic pollution of rivers.
Five days was chosen as an appropriate test period because this is supposedly the longest time that river water takes to travel from source to estuary in the U.
In its sixth report the Royal Commission recommended that the standard set should be 15 parts by weight per million of water. Our experience indicated that in a large majority of cases the volume of river water would exceed 8 times the volume of effluent, and that the figure of 2—0 parts dissolved oxygen per ,, which had been shown to be practicable, would be a safe figure to adopt for the purposes of a general standard, taken in conjunction with the condition that the effluent should not contain more than 3—0 parts per , of suspended solids.
The generally lower values in the U. The BOD is used in measuring waste loadings to treatment plants and in evaluating the BOD-removal efficiency of such treatment systems.
Winkler published the methodology of a simple, accurate and direct dissolved oxygen analytical procedure in , [10].
Since that time, the analysis of dissolved oxygen levels for water has been key to the determination of surface water.
The Winkler method is still one of only two analytical techniques used to calibrate oxygen electrode meters; the other procedure is based on oxygen solubility at saturation as per Henry's law.
There are two recognized methods for the measurement of dissolved oxygen for BOD and a number of other methods not currently internationally recognised as standard methods.
The bottles have traditionally been made of glass, which required cleaning and rinsing between samples. In addition to the various dilutions of BOD samples, this procedure requires dilution water blanks, glucose glutamic acid GGA controls, and seed controls.
The dilution water blank is used to confirm the quality of the dilution water that is used to dilute the other samples.
This is necessary because impurities in the dilution water may cause significant alterations in the results. For measurement of carbonaceous BOD cBOD , a nitrification inhibitor is added after the dilution water has been added to the sample.
When performing the BOD 5 test, it is conventional practice to measure only cBOD because nitrogenous demand does not reflect the oxygen demand from organic matter.
This is because nBOD is generated by the breakdown of proteins, whereas cBOD is produced by the breakdown of organic molecules.
This method is limited to the measurement of the oxygen consumption due only to carbonaceous oxidation. Ammonia oxidation is inhibited.
The sample is kept in a sealed container fitted with a pressure sensor. A substance that absorbs carbon dioxide typically lithium hydroxide is added in the container above the sample level.
The sample is stored in conditions identical to the dilution method. Oxygen is consumed and, as ammonia oxidation is inhibited, carbon dioxide is released.
The total amount of gas, and thus the pressure, decreases because carbon dioxide is absorbed. From the drop of pressure, the sensor electronics computes and displays the consumed quantity of oxygen.
An alternative to measure BOD is the development of biosensors, which are devices for the detection of an analyte that combines a biological component with a physicochemical detector component.
Enzymes are the most widely used biological sensing elements in the fabrication of biosensors. Their application in biosensor construction is limited by the tedious, time-consuming and costly enzyme purification methods.
Microorganisms provide an ideal alternative to these bottlenecks. Many micro organisms useful for BOD assessment are relatively easy to maintain in pure cultures, grow and harvest at low cost.
Moreover, the use of microbes in the field of biosensors has opened up new possibilities and advantages such as ease of handling, preparation and low cost of device.
A number of pure cultures, e. Trichosporon cutaneum, Bacillus cereus, Klebsiella oxytoca, Pseudomonas sp. On the other hand, many workers have immobilized activated sludge, or a mixture of two or three bacterial species and on various membranes for the construction of BOD biosensor.
Search form Search. Sharpspring Tracking Code. Non-biodegradable COD The non-biodegradable COD is a result of soluble substrates that are found in the effluent and escape the wastewater treatment plants in small concentrations as micro pollutants.
Biodegradable COD The biodegradable COD is further divided into readily biodegradable soluble compounds such as volatile nutrients, fatty acids, sugar, selected alcohol and proteins and slowly biodegradable compounds.
Ozone with AOP AOPs are advanced oxidation process utilizing extremely reactive species for the destruction of target pollutants. Ozone tech.
Tailored wastewater treatment projects. Ozone treatment in the textile industry. We Recommend About Ozone. Pharmaceutical residues treatment. Drinking Water.
Air and Odor analysis. Ventilation systems in commercial kitchens.
Bod Deutsch am Main Bod Deutsch. - Beispiele aus dem PONS Wörterbuch (redaktionell geprüft)
Angebot akzeptiert Welcome to my website. I am fortunate to have discovered that after forty years as a psychotherapist and teacher, that I continue to experience a Ronnie OSullivan passion for my work. I was born in Detroit, Michigan in How many persons one has murderedkilled, etc.





Es ist der einfach ausgezeichnete Gedanke
Ich bin endlich, ich tue Abbitte, aber es kommt mir ganz nicht heran. Wer kann noch helfen?
Ich werde besser einfach stillschweigen